Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy

International Journal of Radiation Oncology • Biology • Physics, Elsevier, ISSN 1879-355X

Volume 95, 1, 2016

DOI:10.1016/j.ijrobp.2015.11.015, Dimensions: pub.1038161595, PMID: 26797540,

Authors

Dueck, Jenny * (1) (2) (3)
Lomax, Antony (1) (5)
Aznar, Marianne (2) (3)

* Corresponding author

Affiliations

Organisations

  1. (1) Paul Scherrer Institute, grid.5991.4
  2. (2) Rigshospitalet, grid.475435.4, Capital Region
  3. (3) University of Copenhagen, grid.5254.6, KU
  4. (4) Royal Marsden NHS Foundation Trust, grid.5072.0
  5. (5) ETH Zurich, grid.5801.c
  6. (6) University of Zurich, grid.7400.3

Countries

Denmark

Switzerland

United Kingdom

Continents

Europe

Description

PURPOSE: The safe clinical implementation of pencil beam scanning (PBS) proton therapy for lung tumors is complicated by the delivery uncertainties caused by breathing motion. The purpose of this feasibility study was to investigate whether a voluntary breath-hold technique could limit the delivery uncertainties resulting from interfractional motion. METHODS AND MATERIALS: Data from 15 patients with peripheral lung tumors previously treated with stereotactic radiation therapy were included in this study. The patients had 1 computed tomographic (CT) scan in voluntary breath-hold acquired before treatment and 3 scans during the treatment course. PBS proton treatment plans with 2 fields (2F) and 3 fields (3F), respectively, were calculated based on the planning CT scan and subsequently recalculated on the 3 repeated CT scans. Recalculated plans were considered robust if the V95% (volume receiving ≥95% of the prescribed dose) of the gross target volume (GTV) was within 5% of what was expected from the planning CT data throughout the simulated treatment. RESULTS: A total of 14/15 simulated treatments for both 2F and 3F met the robustness criteria. Reduced V95% was associated with baseline shifts (2F, P=.056; 3F, P=.008) and tumor size (2F, P=.025; 3F, P=.025). Smaller tumors with large baseline shifts were also at risk for reduced V95% (interaction term baseline/size: 2F, P=.005; 3F, P=.002). CONCLUSIONS: The breath-hold approach is a realistic clinical option for treating lung tumors with PBS proton therapy. Potential risk factors for reduced V95% are small targets in combination with large baseline shifts. On the basis of these results, the baseline shift of the tumor should be monitored (eg, through image guided therapy), and appropriate measures should be taken accordingly. The intrafractional motion needs to be investigated to confirm that the breath-hold approach is robust.

Research Categories

Main Subject Area

Fields of Research

Links & Metrics

NORA University Profiles

University of Copenhagen

Danish Open Access Indicator

2016: Unused

Research area: Science & Technology

Danish Bibliometrics Indicator

2016: Level 1

Research area: Science & Technology

Dimensions Citation Indicators

Times Cited: 18

Field Citation Ratio (FCR): 6.8

Relative Citation ratio (RCR): 2.14